ZappⅡ-L
PIEZONIZER Series
Nozzle type ideal for saving space.
Exhibits superior static elimination effects while reducing the flow rate of air compared to previous models.
- Purpose:
- Semiconductors/Electronic devicesLCD panelsAssembly processesPC board mounting processesInspection processesPrinting, coating processesWrapping/Packaging processesResin moldsFilmsGlassLensesDust, foreign matterParts feedersShort rangeSpace-saving
- Function:
-
Product features
- High performance
Even ultra-low air pressure supply, it keeps high performance ionization to compare with ZappII. - Integrated designed nozzle
The point of ion creation is around the tip of nozzle and easy installation with flexible seamless piping. Available length of piping is 100mm or 200mm. - H.V. alarm function
In case high voltage shut down, alarm LED light and alarm output function with non-signaled contact normally open or normally close use. - Cleaning Check [C.C] function
With detecting the abnormal discharge through the discharge emitter, it shows with C.C alarm LED and it links with signal output as normally open.
Power supply, signal cable(standard accessories)
Main Application
For small products that it can’t be supplied with high air pressure.
* Notice: The adjustment of ZappII-L is not same as ZappII, so it cannot use with standard optional nozzles.
Options
ZappII-L exclusive nozzle
Static Decay Characteristics and Ion Balance
(Note1) Using □150mm, 20pF charged plated monitor for measurements.
(Note2) Static elimination time equals the decay time ±1000V→±100V.
(Note3) Distance is measured 50mm from the plate monitor.
(Note4) Above data is actual data not for guaranteed.
Specification
Model | Zapp Ⅱ-L |
---|---|
Input power supply | DC+24 V ±10% |
Electric consumption | 2.4 VA |
Output voltage | AC 2,000 V |
Discharge method | High Frequency AC Corona discharge method |
Ion balance | Below ±15V(Distance at 50mm) |
Alarm output | MOS FET Relay, Normally Opened and Closed contact(NO/NC) Maximum current: 100mA, Voltage: Below 30VDC |
Cleaning Check output | MOS FET Relay, Normally Opened contact(NO)(C.C) Maximum current: 100mA, Voltage: Below 30VDC. |
Discharge stop input(HV-OFF) | Discharge off: Short circuit to 0V, Discharge on: Open circuit (remained voltage below0.5V) |
Supplied Air | Clean Dried Air |
Available air pressure | 0.005 ~ 0.1MPa |
Airflow supply | Maximum 50 ℓ/min (ANR) |
Ozone level | Below 0.1ppm(Supplied air: 30 ℓ/min(ANR) at 50mm) *1 |
Guaranteed operating temperature | 10 to 40 ℃ |
Guaranteed operating humidity | 65%RH or less with no condensation |
Main unit dimensions | 87×18×50mm (W×H×D) only body size |
Weight | Approx 78g |
Accompanying items | Manual, Power supply cable(2.5m) Nozzle is optional. |
*1: Under some environment condition, it sometime makes more high level Ozone, we recommend to use ozone-resistant materials around the tip of nozzle.